SX-2000AO

SX-2000AO Audio Output Unit

  • Overview
  • Specification
  • Downloads

  • The SX-2000AO is an audio output of the matrix system and can be mounted in an EIA equipment rack (2 U size). Multiple units can be decentralized in a whole system. It is equipped with eight audio outputs, and two inputs can be mixed and output. It is also equipped with eight control inputs, and eight control outputs. The SX-2000AO receives audio signals from the audio input unit via digital transmission, but an analog audio input function (1 channel) enables simultaneous all-zone calls for use in emergency situations. Audio output levels are indicated on the level meters provided for each output channel. Volumes can be adjusted for each channel using the volume controls on the front panel or the SX-2000 software. The volume controls can be locked. Any output channel can be monitored using the internal speaker. Two channels of local audio inputs with control inputs are provided as the dedicated audio inputs. Its functions include an amplifier switching function that automatically switches the power amplifier to the standby amplifier if the power amplifier fails, and a surveillance function that self-diagnoses the speaker lines. Equipped with two channels of interfaces for connecting to the Emergency Power Supply units, making it possible to configure the system to operate during a power failure. One control IN/OUT interface allows the number of control inputs and outputs to be increased. The SX-2100AO has two power inputs and can support a dual-redundant power supply system.

  • Specification
    Power Source Usable power supply unit: VX-200PS
    24 V DC (operational range: 20 V – 40 V DC)
    Two power inputs construction enables dual-redundant power supply.
    Current Consumption 1.7 A or less (maximum value in the power operating range)
    1.2 A or less (when operated on 24 V DC)
    Note: But except current consumption of the external equipment of which power is supplied from the unit.
    Indication 18 alphanumeric characters, Level indication (8 outputs, monitor), Status indicators,
    Power indicator, Standby indicator, CPU OFF indicator
    Operation Function button, Output level control, Monitor speaker volume control, ON/OFF switch, Operation button

    PA Link

     

    Audio Output 8 outputs, 0 dB*, suitable load: 600 Ω or above, electronically-balanced output changeable into transformer-balanced output (optional), removable terminal block (12 pins), monitoring possible using built-in speaker
    Audio Output Characteristic Frequency response: 20 Hz – 20 kHz
    Sampling frequency: 48 kHz
    D/A converter: 24 bit
    Connection Cable Shielded Category 5 twisted pair cable (CAT5-STP)
    Maximum Cable Distance 5 m (16.4 ft)
    Usable Amplifier VP-2064, VP-2122, VP-2241 or VP-2421 (VP-200VX is required for each amplifier.)

    Local Audio

    Input Audio Input 2 inputs, 0 dB*, 10 kΩ, electronically-balanced, RJ45 Connector
    Audio Input Characteristic Frequency response: 20 Hz – 20 kHz
    Sampling frequency: 48 kHz
    A/D converter: 24 bit
    Control Input 2 inputs, no-voltage make contact input, open voltage: 12 V DC, short-circuit current: 2 mA, photo coupler input
    Connection Cable Shielded Category 5 twisted pair cable (CAT5-STP)

    SX Link

    Network I/F 2 100BASE-TX circuits, RJ45 connector, decentralized installation possible
    Connection Cable/Device Shielded Category 5 twisted pair cable (CAT5-STP)
    To be connected via the switching hub specified by TOA
    Note: This network must be made completely independent from other LAN.
    Maximum Cable Distance 100 m (109.36 yd) (between this unit and a switching hub)
    Analog Link Input/Output Connector Input: 1 input, RJ45 connector
    Output: 1 output, RJ45 connector
    Connection Cable Shielded Category 5 twisted pair cable (CAT5-STP) (1 pair of audio wire + 1 pair of CPU OFF + 1 pair of control wire (system reset/standby) + 1 pair of connection check wire)
    Maximum Cable Distance Total length of analog link: 800 m (874.89 yd)

    DS Link

    Usable Unit VX-2000DS
    Connector/Cable 2 interface, RJ45 Connector, Shielded Category 5 twisted pair cable (CAT5-STP)
    Maximum Cable Distance 5 m (16.4 ft)

    CI/CO Link

    Usable Unit SX-2000CI or SX-2000CO
    Connector/Cable 1 interface, RJ45 Connector,
    Shielded Category 5 twisted pair cable (CAT5-STP)
    Maximum Cable Distance 800 m (874.89 yd)

    Speaker Line Failure Detection Section

    Connector/Cable Removable terminal block, SP/AMP: 8 pins, STANDBY AMP: 2 pins,
    AWG 24 – AWG 16
    Maximum Input 100 Vrms, 5 Arms
    Fault Detection System Short circuit, open circuit, ground fault
    Method Impedance or End of line
    End of Line In case of normal: Terminated by 470 kΩ between the speaker line and the shield
    In case of open: Opened between the speaker line and the shield
    Impedance Minimum load: 2 kΩ (5 W) at 100 V line
    Control Input 8 inputs, no-voltage make contact input, open voltage: 40 V DC or less, short-circuit current: 2 mA, photo coupler input, removable terminal block (6 pins)
    Control Output 8 outputs, C contact, no-voltage make contact output, relay contact output (withstand voltage: 40 V DC, control current: 2 – 300 mA), removable terminal block (6 pins)
    Operating Temperature 0 ℃ to +40 ℃ (32 ゜F to 104 ゜F)
    Operating Humidity 35 % to 80 %RH (no condensation)
    Finish Panel: Aluminum, black, alumite
    Case: Surface-treated steel plate
    Dimensions 482 (W) × 88.4 (H) × 349 (D) mm (18.98 × 3.48″ × 13.74″)”
    Weight 7.1 kg (15.65 lb)
    Accessory Removable terminal plug (8 pins)