System Management Amplifier
| VM-3240VA | |
|---|---|
| Power source |
230 V AC, 50 / 60 Hz |
| Power / current consumption |
600 W (at rated output), 260 W (EN 62368-1) |
| Frequency response |
50 Hz - 20 kHz |
| Rated output |
240 W total into 6 zones |
| Control input |
Control input 1 - 8: No-Voltage make contact input, open voltage: 24 V DC, short-circuit current: under 2 mA, removable terminal block (14 x 2 pins) |
| Control output |
Control output 1 - 8: Isolated open collector output, withstand voltage: 30 V DC, operating current: under 10 mA, removable terminal block (14 x 2 pins) |
| Operating temperature |
-5 °C to +45 °C |
| Finish |
Aluminium, Steel plate, black |
| Dimensions |
482 x 132.6 x 431.2 mm (W x H x D) |
| Weight |
16.5 kg |
| Inputs |
Input 1 - 3: -50 dBV (MIC) / -10 dB (LINE) (changeable), 600 Ω, electronically balanced, combined XLR connector (female) / phone jack Input 4: -50 dBV (MIC) / -10 dBV (LINE) (changeable), 600 Ω, electronically balanced, on removable terminal block (14 x 2 pins) BGM 1 - 2: -10 dBV, 10 kΩ unbalanced, RCA pin jack (2 x 2) External amplifier Input: 100 V Line, removable terminal block (14 pins) |
| Outputs |
Speaker output 1 – 6: Total within rated output, removable terminal block (14 pins) Direct output from internal or external amplifier, removable terminal block (16 pins) Recording output BGM / Paging 0 dBV, 10 kΩ, unbalanced, RCA pin jack |
| Indicator |
Power, 5-segment bargraph level meter, selected zone, emergency zone active, evacuation active, alert active, front panel microphone active, general fault, CPU fault, menu driven LCD for date, IP address, password etc. |